Available Options:
| • |
Raised Wood Wall Panels -Optional |
• |
Wood Veneer Wall Panels -Optional |
| • |
Laminate Wall Panels -Standard |
• |
Brass Package -Optional |
| • |
Automatic Gate Operator -Optional |
• |
Woodfold Gate -Standard |
| • |
Scissor Gate -Optional (Residential
Only |
|
|
Telephone Cabinet:
| • |
Commercial -Optional |
• |
Residential -Required |
| • |
Stainless Steel -Standard |
• |
Brass -Optional |
General Scope:
To furnish all labor, materials and equipment necessary or required
to fully complete the installation of the elevator as indicated on the
drawings and specifications. This suggested specification is intended
to cover the complete installation of the Genesis Lift Elevator.
ASME/ANSI A17.1 -"Safety Code for Elevators
and Escalators", Part V. Furthermore, materials and construction
shall comply with the current edition of the following codes, standards,
and guidelines. ANSI A17.1 -"Providing accessibility and usability
for physically handicapped people.
System Description:
The elevator assembly shall consist of a power unit, car, guide system,
direct hydraulic or 1:2 cable hydraulic lifting device (determined by
owner), control system, signals and alarms, electrical wiring, and parts
and accessories necessary to provide required performance, operation,
code and safety requirements.
Quality Assurance :
The lift shall meet or exceed applicable regulations of all governing
agencies and be in conformance with:
• Applicable Local Building Code Requirements and regulatory agencies
• Fabricate and install work in compliance
with all applicable authorities.
• File shop drawings and submissions to applicable
agencies as required. Company pre-inspection and regulatory agency inspections
and permits will be made on a timely basis as required. Work will include
all inspections required to ensure licenses are issue
Subcontractor Qualifications :
Execute work of this specification only by a contractor/company who
has adequate product and public liability insurance in excess of one million
dollars. Skilled tradesmen to be employees of the contractor and perform
the work on a timely basis. Employees trained by the manufacturer and
supervised by the elevator contractor.
Substitutions:
No substitutions will be considered until the architect has received
written request for approval. Each request shall include a complete description
of the proposed substitute and any other information needed for consideration.
Preparatory Work By Others:
Provide power unit machine room to meet applicable codes and standards
Permanent power (220 Volt) to operate the elevator
to be provided to a lockable fused/cartridge type disconnect switch with
auxiliary contact/switch for emergency battery lowering if required. Deliver
all wiring in equipment room in conduit. Refer to drawings for permanent
power specifications and location of disconnects.
Provide 15-volt lighting supply and lockout type
disconnect in equipment room for car lights. Provide equipment room with
light and switch inside of room. Refer to drawings for permanent power
specifications and location of disconnects.
Provide an enclosed, plumb and square hoistway with
smooth interior surfaces include for fascias or furring of hoistway interior
as needed.
Provide doors and frames, to be of fire rated construction
and of the type which will provide 2 3/4" clear from back of hoistway
door to inside edge of hoistway sill. Hoistway enclosure doors to have
delayed action closers in compliance with code. Hoistway doors to have
lever type door handles. Provide rough openings as per elevator contractor's
drawings.
Provide equipment room door and door closers. Door
lock set-self locking type. Door to be minimum one (1) hour fire rating.
- Equipment room and hoistway enclosure floors-walls-ceilings
to be of one (1) hour fire rating. Ceiling in equipment room to have
7' clear overhead-minimum.
- Provide substantial and level pit floor slab
to support loads indicated on elevator contractor's shop drawings.
- Provide adequate support for guide rail fastenings
- Provide pit waterproofing or sump pump, if required.
(see elevator contractor)
- Provide 12" or 24" pit (see elevator
contractor)
- Provide 9' minimum overhead (distance from floor
at upper level to underside of roof).
- Provide telephone connection to elevator controller
in equipment room-if required
- Provide cab floor covering.
- Provide fire extinguisher beside strike side
of door jamb inside equipment room.
Hydraulic Power Unit:
- The pump and motor shall be the submersible type
installed inside the oil tank
- The controller shall be mounted per code and
pre-wired and tested before shipment.
- Control circuitry to be "solid state"
and located in car control station panel
- The power unit control valve shall be a two-speed
valve type that includes all hydraulic control per manufacturer specifications
- This valve shall incorporate the following
features:
- Up and down acceleration and deceleration
speed adjustment for smooth starts and stops.
- Smooth stops at each landing shall be an
innate feature of the valve.
- Adjustable pressure relief valve.
- Manually operating DOWN valve to lower elevator
in an emergency.
- Pressure gauge indicating in p.s.i. and bars
- Gate valve to isolate cylinder from pump
unit.
Cylinder and Plunger:
- The cylinder shall be constructed of steel pipe
of a sufficient thickness and suitable safety margin. The top of the
cylinder shall be equipped with a cylinder head with an internal guide
ring and self-adjusting packing.
- The plunger shall be constructed of a steel shaft
of a proper diameter machined true and smooth. The plunger shall be
provided with a s stop electrically welded to the bottom to prevent
the plunger from leaving the cylinder.
Cable-Roped Hydraulic:
- Minimum of two 3/8' IWRC galvanized aircraft
cables. Minimum breaking strength of 14,400 lbs. each.
- Safety Device-Roped Hydraulic:
- A "slack/broken cable" safety device
shall be supplied which will stop and maintain the elevator and
its rated load, if either of the hoisting cables become slack or
break. The safety device shall be reset by the operation of the
elevator in the upward direction. A switch shall be mounted in such
a position as to sense the operation of the safety device, and will
open the safety circuit to the controller to prevent operation of
the elevator in either direction.
Sheave-Roped Hydraulic :
- The 1/2 guide sheave arrangement shall be supplied
with a sheave, guide shoes, roller bearings and adjustable cable guards.
The shave shall be finished with rounded grooves to fit the cables.
Normal Terminals Stopping Devices:
- Normal terminal stopping devices shall optically
sense when at the top and bottom of the runway to stop the car automatically.
Final Limit Switch:
- The elevator shall be equipped with a final limit
switch to cut off all power to the elevator if the upper normal terminal
stopping devices fail.
Guide Rails and Brackets:
- Steel "T" guide rails and brackets
shall be securely fastened to the building structure. Brackets shall
securely hold the guides in a plumb and true position regardless of
car loading. Guides shall be bolted through the hoistway enclosure with
back-up plates, washers and nuts. Subject to architects' alterations
and approval.
Car Sling:
- Car sling shall be fabricated from steel members
with adequate bracing to support the platform and cab. The buffer striking
member on the underside of the car will stop the elevator before the
plunger reaches its down limit of travel. Guide shoes to be solid with
polyurethane inserts.
Wiring:
- All wiring and electrical connections shall comply
with applicable codes, insulated wiring shall have flame retardant and
moisture proof outer covering and shall be run in conduit or electrical
wire ways. Traveling cables shall be flexible and suitably suspended
to relieve strain.
Examination:
- All site dimensions shall be taken to ensure
that tolerances and clearances have been maintained and meet code requirements.
Preparation:
- Pre-inspect the construction and service requirements
for "Work by Others." These requirements will be included
in drawings, diagrams, data sheets and any special instructions before
the work commences.
Warranty:
- The elevator contractor shall provide three (3)
months free service from date of approval by regulatory agency. The
entire elevator and all component parts shall carry a warranty for a
period of one (1) year. The warranty shall be for the replacement at
no cost of defective parts but shall not include the labor costs required
to replace the defective part or parts.
Owner's Instructions & Manual:
- After installation is completed, the contractor
shall instruct the owner in the proper use, operation and maintenance
requirements of the elevator. Instructions to also include emergency
procedures, safety rules and precautions. Contractor shall also supply
the owner with an owner's manual detailing the operating, safety, and
maintenance procedures of the elevator.
Submittals Shop Drawings
- The shop drawings shall show a complete
layout of the elevator equipment detailing dimensions, clearances and
location of machinery. Including the following:
- Drawings showing the dimentsions including
plans, elevations, and sections to show equipment locations and
their relationship to surroundings.
- Load and reaction drawings shall be provided
by the elevator manufacturer and detailed on drawings
Samples
- Provide a sample of color Finishes
Product Data Manufacturer/Product
- The elevator shall be the GENESIS LIFT elevator
manufactured by CENTRAL ELEVATOR CO. INC.
| Rated load: |
750 lbs. |
| Rated speed: |
30 fpm |
| Car platform: |
34"w x 54"d (Inside clear) 84"h |
| Operation: |
Automatic |
| Gate type: |
Woodfold car gate |
| Power supply: |
220 Volt, Single Phase, 30 Amps |
| Travel: |
Commercial -25' Residential -50' |
| Openings: |
As required |
| Lighting: |
115 Volt, 1 Phase, 60 Cycle, 20 Amps |
| Drive system: |
Direct/or/1:2 Cable Hydraulic |
| Pump type: |
Submersible with Blain KV1P/EV100 |
Car
Oak Plastic Laminate Wall Panels
- Provide 1/2" Oak Laminate Cab Panels. Control
wall if needed to be equiped with removable panels for service access.
Ceilings -- Non-removable 1/2" Melamine
with one (1) pot light.
Floor -- Plywood sub-flooring
Handrail -- Oak handrail located below control
panel.
Emergency Operation-Optional -- Equipped
with a battery-powered emergencylowering device and alarm if required,
which can be actuated on the failure of normal building power supply.
Batery will be recharegeable type with an automatic recharging system.
Emergency Light -- The car shall be equipped
with an emergency light that will illuminate automatically in the event
of a main power failure.
Car Operating Panel -- Car operating panel
shall consist of one illuminated button for each landing, an emergency
stop button and an alarm button mounted on a removable stainless panel.
Car Lighting -- The car lighting shall consist
of one (1) low voltage light.
Automatic Lights -- Overhead lights in the
car compartment shall turn ON automatically when the elevator door is
opened and to stay on while the elevator is in use. The elevator lights
will shut off by a timer when the elevator is not in use.
Brass Package -- Provide a package consisting
of a brass car station plate, brass colored pot lights, and brass trim.
Option - Brass Telephone Cabinet -- Provide
a 10"w x12 1/2"h x 3 3/4"d recessed brass colored telephone
box, with a brass colored front.
Door Locks - Interlocks -- Locks shall be
electrically operated and electrically released at floor level and will
remain unlocked until hall or car call is placed. When released, the lock
will drop down and close the electrical circuitry to ensure the elevator
cannot move unless the door is closed and locked.
Hall Call Stations -- Provide a hall call
station with an illuminated call button and stainless steel cover plate
for each landing.
Platform Toe Guard -- A platform toe guard
shall be provided at each car entrance opening to extend below the car
entrance opening for safety.
Leveling Device -- The elevator shall be
provided with a 2-way leveling device which will maintain the car within
1/2" of the landing. Leveling device shall be located in a position
to be inaccessible to unauthorized persons.
Car Gate -- Folding car gate.
|